CR-AG TYPE

  • DC Battery
  • DischargeLoad Bank

SEPHCO CR-AG Series Battery Discharge Test Load Banks

Fully programmable, primarily for lead-acid type battery pack systems.

CR-AG-110B-0501
FEATURES
  • Quality Steel Construction
  • Horizontal Air Cooling
  • Compact Design
  • Intuitive Fully Automatic Control Processor
  • RS232 Interface and USB Logging
  • 5.7” Colour Touch TFT Screen
  • Real Time Storage Data
APPLICATIONS
  • Data Centres
  • UPS Facilities
  • Telecommunication Sites
  • Essential Services
  • Mining
  • Military Establishments

CR-AG Series Description

CR-AG DC load banks are designed for testing batteries to their rated capacity by fully discharging to their safe level, using constant current and to a set discharge time.

Key Features
  • User set-up of cell quantity discharge
  • Real-time storage data – Save ten groups of on-line monitoring, software includes pattern.
  • PC Interface – Control tests directly from a PC and direct on-line monitoring, software includes pattern analysis
  • Powerful communication function – Using RS232 Interface and USB Logging, the user can perform long-term historical data storage and analysis. Create voltage / current histogram, curve charts and test reports including Excel table and Word doc.
Key Features
  • Discharge Monitoring – Monitor pack voltage, cell voltage, charge / discharge current, expire discharge time, charge / discharge capacity of battery
  • Discharge Functions – Set-up parameters of “discharge current”, “discharge time”, “discharge capacity”, “final discharge voltage” of battery pack or cell.
  • Automatic Operation – Operation of the load back is interrupted or test completed if values readings such as discharge voltage, final discharge capacity, discharge time expired or low cell voltage limit has reached the set-up parameters.

SEPHCO CR-AG Series Battery Discharge Test Load Banks

CR-AG A type series
Model24A/150548A/150548A/3010110A/0501110A/1001220A/0501220A/0802380A/054824A/1505220110A/0501
Voltage measurement range of battery string0~30V0~60V0~60V0~135V0~270V0~450V0~60V(48V)0~270V(220V)
0~135V(110V)
Voltage resolution of battery pack0.01V
Voltage testing accuracy0.5%
Discharge current working range2~150A2~150A2~300A2~50A2-100A2~50A2~80A2~50A2~150A(48V)
2~50A(220V)
2~45A(24V)
2~15A(110V)
Constant current discharge voltage range21V~30V42V~60V90~140V180~270V340~450V340~450V42V~60V(48V)
21V~30V(24V)
Discharge powerMax 4.5kwMax 9kwMax.18kwMax 7kwMax 13.5kwMax.13.5kwMax. 21.6kwMax. 19kwMax. 9kwMax.13.5kw
Current testing accuracy1%
Capacity check testing range extensionOne external load added, the testing capacity range doubled
Working voltageAC220±15%
Cooling modeFan Cooling-Horizonal Discharge%
Working environmentTemperature 0℃~40℃; Humidity 20%~80%RH
Storage condition-20℃~70℃ storage and transport
Communication modeRS232 communication, USB Data Logging
Data storage modeUSB Flash Drive
Display mode5.7 inch touch color TFT screen
Instrument dimensions (mm)400*243*301430*248*381400*243*301430*248*381400*243*301430*248*381513*276*405400*243*301
Weight (≤Kg)1317131713172213
Carry methodPortable type
CR-AG B type series
Model24B/150548B/150548B/3010110B/0501110B/1001220B/0501220B/0802380B/054824B/1505220110B/0501
Cell voltage measurement type2V/6V/12V
Cell voltage measurement range2V:0~4V; 6V:0~8V; 12V:0~15V
Cell voltage resolution2V/6V:0.001V; 12V:0.01V
Voltage measurement range of battery string0~30V0~60V0~60V0~135V0~270V0~450V0~60V(48V)0~270V(220V)
0~135V(110V)
String voltage resolution0.01V
Voltage testing accuracy0.5%
Discharge current working range

2~150A2~150A2~300A2~50A2-100A2~50A2~80A2~50A2~150A(48V)
2~50A(220V)
2~45A(24V)
2~15A(110V)
Constant current discharge voltage range21V~30V42V~60V42V~60V90~140V90~140V180~270V340~450V340~450V42V~60V(48V)
21V~30V(24V)
Discharge PowerMax. 4.5kwMax. 9kwMax. 18kwMax. 7kwMax. 13.5kwMax. 13.5kwMax. 21.6kwMax. 19kwMax. 9kwMax.13.5kw
Current testing accuracy1%
Battery capacity check range20Ah~1500 Ah20Ah~1500 Ah20Ah~3000 Ah20~500Ah20~1000Ah20~500Ah20~800Ah20~500Ah20~1500Ah(48V)
20~500Ah(220V)
20~450Ah(24V)
20~150Ah(110V)
Current testing accuracy1%
Capacity check testing range extensionOne external load added, the testing capacity range doubled
Cell data collection methodCable Connection, WIFI optional.
Monitoring current range0~300 A
Working voltageAC220±15%
Cooling modeFan Cooling-Horizonal Discharge
Working environment0℃~40℃; 20%~80%RH
Storage condition-20℃~70℃ storage and transport
Communication modeRS232 communication
Data storage modeUSB Flash Drive
Display mode5.7 inch touch color TFT screen
Instrument dimensions(mm)400*243*301430*248*381400*243*301430*248*381400*243*301430*248*381513*276*405400*243*301
Weight(≤Kg)1317131713172213
Carry methodPortable type