LS-RG TYPE

  • Regenerative Power
  • Load Bank

SEPHCO LS-RG Series Regenerative Power Load Banks

For Permanent Installation, designed and equipped with Smartload automatic load control system with intelligent software to maintain generator/s at a constant set load and absorb regenerative power.

FEATURES
  • Weatherproof to IP54 (NEMA3S)
  • Vertical Air Discharge
  • Compact Design
  • Integrated Control System With Optional Manual Override
  • Modbus Interface Available As An Option
  • Corrosion Resistant Marine Acrylic Finish
  • Stainless Steel Vibration & Immersion Proof Resistors
  • Compact Design
APPLICATIONS
  • Prime Power Generators
  • Cranes and rigs
  • Cable laying vessels
  • Mining

LS-RG Series Description

LS-RG series load banks are fan-cooled, designed for permanent installations, suitable for harsh outdoor environments.

Featuring the Smartload LSM800DRG processor, providing accurate load control with incremental load steps to maintain generators at a constant set load, eliminating wet stacking and cylinder bore glazing. The control software is designed to load and maintain one or several generators on a common bus.

The LSM800DRG controller is coupled to a Power Transducer and CT’s, which monitors generator power via the CT’s and voltage input from the transducer. This voltage signal ranging from 0-10 volts, 5 volts being zero power represents actual power flowing from the generator or back into the generator. A signal voltage of less than 5 volts represents regenerative power being fed back into the generator, whereas a voltage higher than 5 volts represents power fed from the generator to the plant load.

The LSM800DRG controller extrapolates this information to determine the correct value of load steps or kilowatts to be applied to maintain the generator at the desired load, and effectively compensates for any regenerative load or under-loaded condition.

Sephco load banks incorporate immersion proof and vibration proof stainless steel resistors. Safety features include the Sephco “Triple Interlock” load protection system, guarding against fan cooling failure, airflow restriction, high temperature and fan reversal. Unique features of Sephco load banks include circuit breaker protection for each load group and full accessibility to switchgear components and resistors.

Installation of LS-RG type load banks will ensure optimum reliable power from generators, maintaining a constant load or absorb any regenerative power.

Controls

Detailed description, technical data, control type and options are available here.

LSM800DRG Regenerative Power Load Controller

The LSM800DRG controller incorporated in LS-RG type load banks, is coupled to a Power Transducer and CT’s which, monitors generator power via CT’s and voltage input from the transducer. This voltage signal ranging from 0-10 volts, 5 volts being zero power represents actual power flowing from the generator or back into the generator. A signal voltage of less than 5 volts represents regenerative power being fed back into the generator, whereas a voltage higher than 5 volts represents power fed from the generator to the plant load.

The LSM800DRG controller extrapolates this information to determine the correct value of load steps or kilowatts to be applied to maintain the generator at the desired load, and effectively compensates for any regenerative load or under-loaded condition.

External Command Using 0-5V DC or Modbus™

Other versions of the LSM800DRG controller is also available to interface with a PLC load management system using direct 0-5V DC input or a Modbus version where, the load bank is directly controlled and driven by the management system. The controller’s monitoring of the load bank’s safety interlocks and fan cooling is still maintained and managed by the controller.

LS800MPE Manual Override “MIMIC” Control Panel

The LS800MPE is an optional control panel added to the load bank installation for remote, manual override of the load bank for periodical testing and exercising of the generator. Connection is by a simple three-core cable, connected to the load bank’s auxiliary terminals. Featuring a touch-type keypad and LED display, the LS800MPE offers simple operation for manual controllability of the load bank. Selection of operation includes Manual Loading, Auto-Loading and Auto Genset Exercise modes. The exercising function is programmable by setting up a load routine with time duration. The LED display indicates the kilowatt value activated at the load bank during any of the switching operations. Additional LED’s display mode selection and the status of the load bank, including fan-cooling fault.

The remote “Enable” signal connected to the LSM800MB prevents operation of the Mimic panel when the generating system is operating in the emergency back-up mode, preventing inadvertent use of the load bank. When the “Enable” signal is closed, the control system reverts back to auto-loading of the generator.

SEPHCO LS-RG Series Load Bank Dimensions

LSOV SERIES 20kW To 125kW

LSM800DRG

MODEL No
RATING
LOAD STEPS
DIM.A
DIM.B
DIM.C
WEIGHT
NOISE LEVEL

LS0V125RG

125KW

25KW

745

835

985

156 KG

78dBa @ 1M

LS0V100RG

100KW

10KW

745

835

985

156 KG

78dBa @ 1M

LS0V75RG

75KW

10KW

745

835

985

145 KG

69dBa @ 1M

LS0V60RG

60KW

15KW

745

835

985

135 KG

69dBa @ 1M

LS0V50RG

50KW

10KW

745

835

985

135 KG

69dBa @ 1M

LS0V40RG

40KW

10KW

745

835

985

130 KG

69dBa @ 1M

LS0V30RG

30KW

5KW

745

835

985

130 KG

69dBa @ 1M

LS0V25RG

25KW

5KW

745

835

985

125 KG

69dBa @ 1M

LS0V20RG

20KW

5KW

745

835

985

125 KG

69dBa @ 1M

LS2V-RG, LS4V-RG, LS6V-RG SERIES 150kW To 600kW

LSM800DRG

MODEL No
RATING
LOAD STEPS
DIM.A
DIM.B
DIM.C
AIR DISCHARGE
NOISE LEVEL
WEIGHT

LS6V600RG

600KW

50KW

1405

1310

1720

9.0 cu.m/s

88.0dBA @1M

650 KG

LS6V500RG

500KW

50KW

1405

1310

1720

9.0 cu.m/s

88.0dBA @1M

600 KG

LS6V400RG

400KW

40KW

1305

1175

1510

6.6 cu.m/s

80.5dBA @1M

450 KG

LS6V360RG

360KW

40KW

1305

1175

1510

6.6 cu.m/s

80.5dBA @1M

425 KG

LS6V320RG

320KW

40KW

1305

1175

1510

6.6 cu.m/s

80.5dBA @1M

400 KG

LS6V28RG

280KW

40KW

1305

1175

1510

6.6 cu.m/s

80.5dBA @1M

375 KG.

LS6V240RG

240KW

40KW

1305

1175

1510

6.6 cu.m/s

80.5dBA @1M

345 KG

LS6V200RG

200KW

25KW

1105

975

1400

4.7 cu.m/s

72 dBA @1M

320 KG

LS6V150RG

150KW

25KW

1105

975

1400

4.7 cu.m/s

72 dBA @1M

300 KG

LS12V-RG SERIES 800kW to 1200kW

LSM800DRG

MODEL No
RATING
LOAD STEPS
DIM.A
DIM.B
DIM.C
AIR DISCHARGE
NOISE LEVEL
WEIGHT

LS12V1200RG

1200KW

50KW

2405

1310

1865

17.9 cu.m/s

91 dBA @1M

1200 KG

LS12V1000RG

1000KW

50KW

2405

1310

1865

17.9 cu.m/s

91 dBA @1M

1000 KG

LS12V800RG

800KW

50KW

2405

1310

1865

17.9 cu.m/s

91 dBA @1M

946 KG

Operation & Accessories

For Permanent Installation To Periodically Test & Exercise Stand-By Generators & UPS Systems. Weatherproof Construction, Complete With Controls.

Engineers Submittal Specifications

For Permanent Installation To Periodically Test & Exercise Stand-By Generators & UPS Systems. Weatherproof Construction, Complete With Controls.

(AU Callers)